Italiano English Russian Spanish



Site map-Contacts



 Datasheets Infinity  Installation Tubes
Catalogue

Example


Installation ø20 - ø25 - ø32 - ø40
Fittings of ø20 - ø25 - ø32 - ø40 are pre-assembled. Tubes of 4 mt are pre-coated, calibrated and burred.
Push tube into the fitting for automatic connection.
In case of fitting disassembling, use the torques as in the chart to re-assemble the fitting.
Diameter Torque
20 300 cN.m
25 300 cN.m
32 400 cN.m
40 650 cN.m

Installation ø50 - ø63
Fittings of ø50 - ø63 are pre-assembled with nut untwisted to help tube connection. Tubes of 4 mt are pre-coated, calibrated and burred.
Push tube into the fitting for connection and tighten the nut using torques as in the chart.
Diameter
Torque
50 75 N.m
63 75 N.m

Installation ø110
Fittings of ø110 are pre-assembled with four screws untwisted to help tube connection. Tubes of 4 mt are pre-coated, calibrated and burred.
Push tube into the fitting for automatic connection and screw up in the suggested sequence. Tightening torque 30Nm.
 

Tube Connection

The correct connection of tube is confirmed by the position of the arrow pre-stamp. If you need to cut the tube, mark the distance of tube to insert in the fitting.

Diameter L mm
20 31,5 mm
25 38,5 mm
32 46 mm
40 52 mm
50 63,5 mm
63 75,5 mm
110 125,5 mm
 


The collars are the base components to clamp the installation tubes, for a correct utilisation, they have to be positioned on the tubes at a distance of two meters one from the other.

Installation of the art. 90860-90861
Credits